Used Leica TC 1205+ 5″ Total Station

Package Includes with Accessories

• Heavy Wooden Tripod
• Prism and With Pole
• 1 Battery and Charger Set

Features and Benefits

• Angular accuracy of 5’’(1.5 mgon)
• Single-prism range 3000 m, 1 mm+1.5 ppm accuracy
• Reflectorless sheet 250 m
• Motorized Rotating speed: 45° / s
• Shortest measurable distance: 1.5m
• CompactFlash card 256MB
• Battery Li-Ion 7.4V/4400mAh
• Data formats GSI / LandXML / user definable ASCII formats
• High-resolution backlit display
• IP54 dustproof and water
• Operating time Up to 15 hours Battery life

Download Datasheets

Download Brochures

AED11,000.00

Product Description

Leica TCP 1205 Manual Target Total Station

Superb Measurement Technology
Measurements of high angles precise and accurate measurements long distance, supported for a quick and perfect systems Automatic aims at the prism. You will work faster, more rigorously and under less pressure.

Simple Operation
Intuitive interface, powerful database routines and programs loaded in total station: simplicity and identical in TPS and GPS.

Large Graphic Display
Easy viewing of entire surveyed area and immediate access to all measured data. You see exactly what you’ve done and what you’ve still to do.

Total Flexibility
Configure and program the TPS1200 as you wish, for their applications, and export the infomation needed.

A Complete Series
TPS1200 total stations cover a range of models and options. Select the ones that suit you best.

Use TPS1200 For Everything
Use TPS1200 total stations for surveying, engineering, stakeout, topo, monitoring etc. Combine them with GNSS. Benefit from huge productivity of System 1200.

Find the Prism Automatically
PowerSearch finds reflectors within seconds no matter where they are. With PowerSearch activated, TPS1200 rotates and sends out a vertical laser fan. As soon as the fan strikes a prism TPS1200 stops rotating, ATR takes over and fine points – all fully automatically.

Specifications:

Angle measurement
Accuracy (standard deviation ISO 17123- 3) 5“ (1.5 mgon)
Display least count: 0.1“ (0.5 mgon)
Method absolute, continuous, diametrical
Compensator Working range: 4’ (0.07 gon)
Setting accuracy: 1.5” (0.5 mgon)
Method: centralized dual axis compensator
Distance measurement (IR) (Light haze, visibility about 20 km; or moderate sunlight, slight heat shimmer)
Standard prism (GPR1): 3000 m (10000 ft)
3 standard prisms (GPR1): 4500 m (14700 ft)
360° prism (GRZ4): 1500 m (5000 ft)
360° mini prism (GRZ101): 800 m (2600 ft)
Mini prism (GMP101): 1200 m (4000 ft)
Reflector tape (60 mm x 60mm): 250 m (800 ft)
Shortest measuring distance: 1.5 m
Accuracy (standard deviation ISO 17123-4) / Measure time Standard mode: 2 mm + 2 ppm / typ. 1.5 s
Fast mode: 5 mm + 2 ppm / typ. 0.8 s
Tracking mode: 5 mm + 2 ppm / typ. < 0.15 s
Averaging mode: 2 mm + 2 ppm
Display resolution: 0.1 mm
Method Principle: Phase measurement
Type: Coaxial, infrared laser
Carrier wave: 780 nm
Measuring system: Special frequency system basis 100 MHz = 1.5 m
PinPoint reflectorless distance measurement (RL) (Object in shade, or sky overcast)
Range PinPoint R100 Kodak Gray Card, 90% reflective: 170 m (560 ft)
Kodak Gray Card, 18% reflective: 100 m (330 ft)
Range PinPoint R300 Kodak Gray Card, 90% reflective: 500 m (1640 ft)
Kodak Gray Card, 18% reflective: 300 m (990 ft)
Range of measurement: 1.5 m to 760 m
Display unambiguous: up to 760 m
Accuracy (standard deviation ISO 17123-4) / Measure time 0 m – 500 m: 3 mm + 2 ppm / typ. 3-6 s, max. 12 s
> 500 m: 5 mm + 2 ppm / typ. 3-6 s, max. 12 s
Atmospheric conditions: Object in shade, sky overcast
Display resolution: 0.1 mm
Laser dot size At 20 m: 7 mm x 14 mm
At 100 m: 12 mm x 40 mm
At 200 m: 25 mm x 80 mm
Method Type: Coaxial, visible red laser
Carrier wave: 670 nm
Measuring system PinPoint R100: Special frequency system basis 100 MHz ≅ 1.5 m
Measuring system PinPoint R300: System analyzer basis 100 MHz – 150 MHz
Motorized
Maximum speed 45° / s
Automatic Target Recognition (ATR)
Range ATR / Lock Mode Standard prism (GPR1): 1000 m (3300 ft) / 800 m (2600 ft)
360° prism (GRZ4): 600 m (2000 ft) / 500 m (1600 ft)
360° mini prism (GRZ101): 350 m (1150 ft) / 300 m (1000 ft)
Mini prism (GMP101): 500 m (1600 ft) / 400 m (1300 ft)
Reflector tape (60 mm x 60mm): 55 m (175ft) / –
Shortest measuring distance: 1.5 m / 5 m
Accuracy / Measure time Positioning accuracy (GPR1): < 2 mm
Measure time (GPR1): 3-4 s
Maximum speed (LOCK mode) Tangential (standard mode): 5 m / s at 20 m, 25 m / s at 100 m
Radial (tracking mode): 5 m / s
Searching Search time in field of view: Typ. 3 s
Field of view: 1° 30’ (1.66 gon)
Definable search windows: Yes
Method Principle: Digital image processing
Type: infrared laser
PowerSearch (PS)
Range Standard prism (GPR1): 200 m (650 ft)
360° prism (GRZ4): 200 m (650 ft) (perfectly aligned to the instrument)
Mini prism (GMP101): 100 m (330 ft)
Shortest measuring distance: 1.5 m
Searching Search time: Typ. < 10 s
Default search area: Hz: 400 gon V: 40 gon
Definable search windows: Yes
Method Principle: Digital signal processing
Type: infrared laser
Guide Light (EGL)
Range Working range: 5 m – 150 m
Accuracy Positioning accuracy: 5 cm at 100 m
General data
Telescope Magnification: 30 x
Free objective aperture: 40 mm
Field of view: 1°30’ (1.66 gon) / 2.7 m at 100 m
Focusing range: 1.7 m to infinity
Keyboard and Display Display: ¼ VGA (320*240 pixels), graphic LCD, illumination, touch screen (optional)
Keyboard: 34 keys (12 function keys, 12 alphanumeric keys), illumination
Angle display: 360° ’ “, 360° decimal, 400 gon, 6400 mil, V%
Distance display: meter, int. ft, int. ft/inch, US ft, US ft/inch
Position: face I standard / face II optional
Data storage Internal memory: 32 MB (optional)
Memory card: CompactFlash cards (32 MB and 256 MB)
Number of data records: 1750 / MB
Interface: RS232, BluetoothTM (optional)
Laser plummet Centering accuracy: 1.5 mm at 1.5 m (deviation from plumb line)
Laser dot diameter: 2.5 mm at 1.5 m
Endless drives Number of drives: 1 horizontal / 1 vertical
Circular level Sensitivity: 6’ / 2 mm
Internal Battery (GEB221) Type: Lithium-Ion
Voltage: 7.4 V
Capacity: 3.8 Ah
Operating time: Typ. 6 – 8 h
Dimensions Tilting axis height: 196 mm above tribrach
Height: 345 mm
Width: 226 mm
Length: 203 mm
Weights Total station: 4.8 – 5.5 kg (depending on type and options)
Battery (GEB221): 0.2 kg
Tribrach (GDF121): 0.8 kg
Environmental specifications Working temperature range: -20°C to +50°C
Storage temperature range: -40°C to +70°C
Dust / water (IEC 60529): IP54
Humidity: 95%, non-condensing

Leica TCP 1205+ Manual Target Total Station

Leica TCP 1205+ Manual Target Total Station - Calibrated By A Leica Service Center
SKU: TCP1205+ Condition: Refurbished
Warranty: 90 Day Exchange

Brand

Leica

There are no reviews yet.